INFICON VORTEX DUAL OPERATING MANUAL Pdf Download (2024)

INFICON VORTEX DUAL OPERATING MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. Inficon Manuals
  4. Test Equipment
  5. VORTEX
  6. Operating manual

Refrigerant recovery machine

Hide thumbs Also See for Vortex Dual:

  • Operating manual (16 pages)
1
2
Table Of Contents 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
  • Contents
  • Table of Contents
  • Troubleshooting
  • Bookmarks

Table of Contents

  • Table of Contents

  • Safety First

  • Product Safety

  • Responsibility

  • Trademarks

  • EPA Certification

  • Declaration of Conformity

  • 1 Safety Precautions
  • 2 Specifications, Features and Warranty
    • Vortex Dual Specifications

    • Warranty

  • 3 Setup and Operation
    • Getting Started

    • Standard Recovery Operation

    • Purging Vortex Dual

    • Push-Pull Operation

    • Cooling the Recovery Tank

    • Special Operating Notes

  • 4 Maintenance
  • 5 Troubleshooting
  • 6 Service
  • 7 EPA Requirements (PN 714-202-G1 Only)

Advertisem*nt

Quick Links

  • 1 Specifications, Features and Warranty
  • 2 Setup and Operation
  • 3 Getting Started
  • 4 Standard Recovery Operation
  • 5 Purging Vortex Dual
  • 6 Maintenance
  • 7 Troubleshooting
  • 8 Service
  • Download this manual

O P E R A T I N G

M A N U A L

Vortex

Dual

®

Refrigerant Recovery Machine

English· Español·Français·Deutsch·Italiano·Nederlands·Svenska·中文

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

INFICON VORTEX DUAL OPERATING MANUAL Pdf Download (2)

Subscribe to Our Youtube Channel

Related Manuals for Inficon Vortex Dual

  • Air Conditioner Inficon VORTEX Operating Manual

    Refrigerant recovery machine (16 pages)

  • Test Equipment Inficon MPG400 Operating Manual

    Inverted magnetron pirani gauge (32 pages)

  • Test Equipment Inficon 122 20 Translation Of The Original Operating Instructions

    Test leak for sniffer leak detection (18 pages)

  • Test Equipment Inficon MCT150 Operating Manual

    Monitor calibration tool (64 pages)

  • Test Equipment Inficon Quantus LP100 Operating Manual

    Gas analysis system (40 pages)

  • Test Equipment Inficon 122 20 Operating Instruction

    Test leck for snifferleak testing (12 pages)

  • Test Equipment Inficon UL3000 Fab PLUS Operating Instructions Manual

    Helium leak detector with ultratest sensor technology (152 pages)

  • Test Equipment Inficon TC1000 Operating Manual

    Test chamber for hermetically sealed parts (22 pages)

  • Test Equipment Inficon TL3-5 Operating Manual

    Adjustable helium test leak (32 pages)

  • Test Equipment Inficon FTC3000 Translation Of The Original Operating Instructions

    Flexible test chamber for elt3000 (42 pages)

  • Test Equipment Inficon E-Check Translation Of The Original Operating Instructions

    Calibration leak for elt3000 (18 pages)

  • Test Equipment Inficon TGF10 User Manual

    Tracer gas filler (36 pages)

Summary of Contents for Inficon Vortex Dual

  • Page 1 O P E R A T I N G M A N U A L Vortex Dual ® Refrigerant Recovery Machine English· Español·Français·Deutsch·Italiano·Nederlands·Svenska·中文...
  • Page 2 Användarhandbok för Vortex Dual ....中文 Vortex Dual 操作手册 ......
  • Page 3: Table Of Contents

    Standard Recovery Operation ....Purging Vortex Dual ......
  • Page 4: Safety First

    (servicing) instructions in this manual. Product Safety Vortex Dual is a recovery machine for a broad range of refrigerants. Recovering refrigerants into separate storage tanks involves a process of gas compression, resulting in high pressures within the machine, the connecting hoses, and the storage tank.
  • Page 5: Epa Certification

    Equipment Description ....Vortex Dual Refrigerant Recovery Machine Model Number.
  • Page 6: Safety Precautions

    Disconnect power before moving or servicing Vortex Dual. The risk of electric shock and exposure to hot compressor parts is possible if the Vortex Dual covers are removed. Vortex Dual should only be opened by a qualified technician who has been trained in basic electronics and refrigeration.
  • Page 7: Specifications, Features And Warranty

    14 AWG or larger for 115 V (ac) or 1.00 mm or larger for 230 V (ac). Do not use Vortex Dual near open containers of gasoline or other flammable liquids. This product is designed for use with refrigerants only and is not intended for use with any combustible refrigerants.
  • Page 8: Warranty

    Failure to use the included filter will void the compressor warranty. INFICON liability is limited to repairing or replacing, at its option, a defective machine or part. If a defect arises, a valid claim must be received by INFICON, with transportation prepaid, no later than thirty (30) days after the warranty period expires.
  • Page 9 80% of its capacity, by weight. Check the tank weight before transporting. Do not allow Vortex Dual to recover large amounts of liquid too quickly. NOTE: When a significant amount of liquid is present and enters the recovery machine too quickly during the refrigerant recovery process, this is sometimes referred to in the field as a "liquid slug"...
  • Page 10: Standard Recovery Operation

    FILTER SCALE LIQUID Make sure the hose connecting Vortex Dual to the recovery tank is attached to the LIQUID port (LP). OPEN the LP valve on the tank. Keep the VAPOR port CLOSED. Rotate the INLET valve (V1) to CLOSE.
  • Page 11: Purging Vortex Dual

    Figure Turn on Vortex Dual and slowly rotate the INLET valve (V1) to PURGE. Run Vortex Dual and monitor the LP gauge until a vacuum of 20 In/Hg (0.7 bar) or more is achieved. Turn off Vortex Dual and immediately close the valves on the recovery tank.
  • Page 12: Push-Pull Operation

    Vortex Dual Operating Manual 3.4 Push-Pull Operation The push-pull recovery method is used to move large amounts of liquid refrigerant. During this process, the recovery unit pulls vapor from the recovery cylinder and produces high pressure discharge gas that pushes liquid out of the HVAC system and back into the recovery cylinder.
  • Page 13: Cooling The Recovery Tank

    Vortex Dual Operating Manual 3.5 Cooling The Recovery Tank Vortex Dual can be used to pre-cool (or sub-cool) the recovery tank, if the head pressure is too high to complete the recovery process. If the ambient pressure is too high, high head pressure can occur when working with certain refrigerants that have a high vapor pressure.
  • Page 14: Special Operating Notes

    4.0 Maintenance With minimal but important maintenance, Vortex Dual can provide many seasons of reliable service. After each use, clean Vortex Dual with a damp cloth to remove dirt and oils. Do not use gasoline or other hazardous solvents to clean Vortex Dual;...
  • Page 15: Service

    All service work must be performed at an INFICON-approved facility to maintain the safety rating and the warranty. If defective, do not return Vortex Dual directly to the factory. For technical assistance or service information, contact INFICON or your wholesaler.
  • Page 16: Epa Requirements (Pn 714-202-G1 Only)

    Certification requirements for recovery equipment and technicians have also been established. The INFICON Vortex Dual has been EPA Certified for use by an independent laboratory. The EPA has also established Evacuation Requirements for HVAC/R equipment used for service, to ensure that any release of CFCs or HCFCs to the atmosphere is minimized.
  • Page 17 Vortex Dual Operating Manual Table 7-1 EPA Requirements REQUIRED INCHES OF HG TYPE OF APPLIANCE VACUUM HCFC-22 appliance generally containing less than 200 pounds of refrigerant HCFC-22 appliance generally containing 200 pounds or more or refrigerant Other high pressure appliance generally containing less...
INFICON VORTEX DUAL OPERATING MANUAL Pdf Download (2024)
Top Articles
Latest Posts
Article information

Author: Arline Emard IV

Last Updated:

Views: 6220

Rating: 4.1 / 5 (72 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Arline Emard IV

Birthday: 1996-07-10

Address: 8912 Hintz Shore, West Louie, AZ 69363-0747

Phone: +13454700762376

Job: Administration Technician

Hobby: Paintball, Horseback riding, Cycling, Running, Macrame, Playing musical instruments, Soapmaking

Introduction: My name is Arline Emard IV, I am a cheerful, gorgeous, colorful, joyous, excited, super, inquisitive person who loves writing and wants to share my knowledge and understanding with you.